Abstract

Vacuum breakdown is a very common problem during the operation of any electron gun, more so for e-guns used for vacuum evaporation. This not only spoils the coating or welding job but also causes damage to the electronics of the power system. This paper discusses an approach to attenuate the breakdown current near the gun itself, so that the surge does not propagate to cause any detrimental effect on the power source and thereby on the job. In this paper, ferrite beads on both the feed lines have been used to suppress the high frequency content and reduce the amplitude of the breakdown signal. An induction coil sensor has been designed to monitor the breakdown signal. The high frequency surge in the MHz range could be attenuated to a lower range of KHz by use of ferrite bead. A detailed quantitative analysis of the breakdown signal has been presented in this paper.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.