Abstract

The attenuation characteristics of a slit resonator that combined the adaptive feedback ANC system at a ventilation aperture of the package for leakage noise is investigated. The discrete tones radiated from an AC axial flow fan are controlled by DSP using Filtered-X Least Mean Square algorithm. The attenuation is found at the range of: 3dB-14dB with circular slit resonator, 2dB-15dB with elliptic slit resonator. Results of measurement show that the proposed system can achieve TNR(Tone to Noise Ratio) and PR(Prominence Ratio) under threshold effectively.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.