Abstract

Science and Technology for Hydroponics can be use in a limited land areas . This Hydroponic System uses a pump load to drain water continuously using PLN power and result in a waste of electricity costs. therefore this study applies a Hybrid ATS (Automatic Transfer Switch) System using PLTS power and PLN power for pump loads that drain water continuously using internet of things technology so that it can be monitored at any time. The ATS System performs Automatic Switching (disconnect flow a electric) If the PLTS power less than <10V and connects PLN power so that that the pump load remains on until the PLTS power recovers and the Blynk application sends a notification that the PLTS flow condition is cut off and PLN is connected. Error reading from the INA219 sensor at the voltage output is 0.4 -0.6% and the current is 3.0%. The TDS sensor reads the PPM value of hydroponic water from 08.00 to 18.00 with an average 0f 291.38 PPM.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.