Abstract

Both echocardiography and CMR imaging are used to quantify longitudinal function. Inter-method variability for mitral (MAPSE) and tricuspid (TAPSE) annular plane systolic excursion, and variability between directly measured MAPSE and TAPSE and as based on atrioventricular plane displacement (AVPD) analysis by CMR, are, however, not known. This study, therefore, assessed inter-method variability and variability between annular plane systolic excursion and AVPD-based values in a healthy adult population. Echocardiography and CMR were performed in 111 adults (35 [32-38] years). Method comparisons were assessed with Deming regression, Bland-Altman analysis and coefficient of variation. Observer reproducibility was assessed by the concordance correlation coefficient. Echocardiography and semi-automatic CMR agreed on MAPSE (17±2mm vs. 17±2mm, p=0.1) and TAPSE (25±3mm vs. 25±3mm, p=0.5), correlated highly between methods (fitted-slope 1.22 [95% CI 1.07-1.38] and 1.12 [95% CI 0.95-1.29]) and showed low bias (0.42 [95% CI-2.05 to 2.88] and-0.18 [95% CI-4.78 to 4.43]). Intra-/inter-observer reproducibility was high for both methods for both MAPSE (echocardiography 0.96/0.86; CMR 0.87/0.85) and TAPSE (echocardiography 0.96/0.95; CMR 0.97/0.96). MAPSE (16±2mm vs. 17±2mm; p<0.001) and TAPSE (24±3 vs. 25±3mm; p<0.001) based on AVPD were similar but statistically different compared with semi-automatic CMR. Echocardiography and semi-automatic CMR have low variability and provide similar values for MAPSE and TAPSE and are thus interchangeable for follow-up studies. Lateral values based on tracked data from AVPD analysis are not clinically significantly different and could be used as a representation of annular displacement.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call