Abstract

Variability of the bipolar atrial electrogram amplitude may affect voltage maps created during ablation procedures, and thus also the extent of ablations. Therefore, the aim of the study was to assess the beat-to-beat electrogram amplitude variability in the left atrium in patients undergoing atrial fibrillation ablation. In 11 patients undergoing ablation for atrial fibrillation, 362 mapping points were collected in two series. At each point, three consecutive beats were recorded and verified including the bipolar electrogram amplitude, contact force (CF), and orientation of the catheter tip. The repeatability and reproducibility of obtained measurements between consecutive beats and series were assessed by the Pearson correlation coefficient (r), the Bland-Altman test, repeatability coefficient (RC), relative standard deviation (RSD), and concordance correlation coefficient (CCC). A total of 1086 beats were analyzed. The correlation coefficient for bipolar atrial electrogram amplitude for the first two beats, and for the first and the third beats were 0.94 and 0.86, respectively. The average of differences between the first two beats and between the first and the third beats were 0.06and 0.13 mV with 95% limits of agreement (LoA)within ±0.98and ±1.74 mV, respectively. For CF values ≤5and ≥20 g, the 95% LoA were narrower compared to other CF rangesand were ±0.49and ±0.71 mV from the average value, respectively. When the analyzes were performed within the predefined ranges of bipolar electrogram amplitude: 0.05-1; 1-2; 2-3 mV, the 95% LoA were within ±0.33, ±0.98, and ±0.84 mV from the average value, respectively. RC and RSD were 1.41 mV and 20.8%, respectively. For repeated measurement between series,CCC ranged from 0.67 to 0.71 and the 95% LoA were within ±2.7 to 2.9 mV from the average value. Bipolar atrial electrogram amplitude recorded at a given site during ablation procedures is variable to an extent that may be clinically relevant. The magnitude of the observed variability is greater during remapping.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.