Abstract

We show that ATP-sensitive K + channels of excised inside-out membrane patches of rat ventricular myocytes show considerable variation in their sensitivity to ATP. In 102 different membrane patches IC 50 values ranged from 9 to 580 μM ATP and Hill coefficient from 1% to 6.41% of patches showed openings of ATP-sensitive K + channels in the presence of 1 mM ATP. These results considerably widen the range of internal ATP concentrations over which one might expect activation of the ATP-sensitive K + current in cardiac myocytes.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call