Abstract

The adenosine triphosphate (ATP) bioluminescence rapid determination method may be useful for enumerating the total viable count (TVC) in soy sauce, as it has been previously used in food and beverages for sanitation with good precision. However, many factors interfere with the correlation between total aerobic plate counts and ATP bioluminescence. This study investigated these interfering factors, including ingredients of soy sauce and bacteria at different physiological stages. Using the ATP bioluminescence method, TVC was obtained within 4 h, compared to 48 h required for the conventional aerobic plate count (APC) method. Our results also indicated a high correlation coefficient (r = 0.90) between total aerobic plate counts and ATP bioluminescence after filtration and resuscitation with special medium. The limit of quantification of the novel detection method is 100 CFU/mL; there is a good linear correlation between the bioluminescence intensity and TVC in soy sauce in the range 1 × 10(2) -3 × 10(4) CFU/mL and even wider. The method employed a luminescence recorder (Tristar LB-941) and 96-well plates and could analyse 50-100 samples simultaneously at low cost. In this study, we evaluated and eliminated the interfering factors and made the ATP bioluminescence rapid method available for enumerating TVC in soy sauce.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call