Abstract
AbstractIn constructing all kinds of equipment and steel structure, parts with discontinuities such as weld defects formed in the welded structure can generate fatigue cracks that results in damage or accidents. In this study, weld zones are investigated with X-rays and the latent images are put on film. Weld zone defects can be verified by developing the film. As weld defects are investigated by radiographic testing and correlated with the welding condition, more appropriate welding conditions can be found. According to the result of X-ray radiographic inspection of butt welding ATOS 80 high-strength steel with a thickness of 12mm, the best conditions for welding without creating weld defects are 4 weld-passes, a protective gas of 20% CO 2 and 80% Ar, a protective gas flow of 20L/min, a welding current of 200A, an arc voltage of 24V, a welding speed of 14.4cm/min, a welding rod angle of 50°, a welding gap of 5 mm with a ceramic base, and sand pre-heating to 160° Celsius prior to welding.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
More From: Journal of The Korean Society of Manufacturing Technology Engineers
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.