Abstract

The main characteristics of CWF (coal-water fuel) sprays produced by an internal mixing twin fluid atomizer are analyzed. Drop size and concentration have been determined by a laser light diffraction method (Malvern) and a high-speed photographic technique. The combined use of different experimental methods, along with the numerical inversion of line-of-sight measurements, allows a reliable characterization of the spray structure along radial and axial coordinates. The mean drop size depends essentially on the dynamic head of the atomizing air, the surface tension, and the coal particle size distribution of the slurry fuel. No clear effect of the CWF's apparent viscosity has been detected. The equation developed to correlate mean drop size takes all relevant factors into account and was derived for a nozzle operating with sonic flow in the exit ports.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.