Abstract

We present a novel approach, based on atomic force microscopy, for exploring the local elastic properties of the membrane-skeleton complex in living cells. Three major elements constitute the basis for the proposed method: (1) pulling the cell membrane by increasing the adhesion of the tip to the cell surface provided via appropriate tip modification; (2) measuring force-distance curves with emphasis on selecting the appropriate withdrawal regions for analysis; (3) fitting of the theoretical model for axisymmetric bending of an annular thick plate to the experimental curve in the withdrawal region, prior to the detachment point of the tip from the cell membrane. This approach, applied to human erythrocytes, suggests a complimentary technique to the commonly used methods. The local use of this methodology for determining the bending modulus of the cell membrane of the human erythrocyte yields a value of (2.07+/-0.32) x 10(-19) J.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.