Abstract
Atomic chlorine concentrations in Cl2 and CF3Cl plasmas have been measured using both infrared absorption spectroscopy and optical emission actinometry. These measurements were made over a range of plasma conditions including plasma excitation frequencies of 72 kHz–13.5 MHz, power inputs of 10–100 W, and pressures of 200–800 mTorr. In Cl2 plasmas, the technique of optical emission actinometry misrepresents atomic chlorine concentration changes by nearly an order of magnitude. The errors in the actinometry technique are believed to result from excited state Cl production by electron impact dissociation of Cl2. A simple model for Cl emission is in good agreement with the experimental observations. In CF3Cl discharges, the technique of optical emission actinometry is shown to accurately represent variations in atomic chlorine concentration with changing process conditions.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.