Abstract

Atmospheric levels of atomic mercury pollution were measured using spectroscopic techniques in the city of Guangzhou, Guangdong Province, China. Assessments were mainly performed at ground level using a portable (vehicle mounted or hand carried) Zeeman modulation correlation spectrometer (Lumex RA-915M), and the results are given in easily comprehensible diagrams. Measurements were made with continuous recording in car traverses along major roads which cross the city, but also at selected spots, such as at a university campus with laboratory buildings. Further, pollution levels at different locations were recorded when walking through a major and a small hospital. While concentrations in the city in the range 3–10 ng/m3 were typical, and strongly dependent on the traffic situation, very high concentrations (up to 1300 ng/m3) were found at certain indoor hospital locations, again drawing attention to the fact that high mercury levels due to inadequate handling routines can remain undetected but could readily be eliminated by adequate measurements and subsequent sanitation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.