Abstract

Atmospheric corrosion of tin coating on copper was explored to understand the differences in corrosion behavior between the skyward and earthward surfaces of the tin coating. Results show that average corrosion rate of the tin coating was 0.578 ± 0.051 and 1.137 ± 0.166 μm■y−1 after one year and two years of exposure in Xiangtan, China, respectively. Corrosion rate of the tin coating during the second year of exposure was higher than that during the first year. SnO2 was the main corrosion product of the tin coating. Localized corrosion vulneravbilty of the skyward surface was higher than that of the earthward surface during the first year of exposure, but it became lower than the latter during the second year. During the first year of exposure, icorr values of the skyward and earthward surfaces were relatively low, but they sharply increased during the second year of exposure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.