Abstract

The objective of this study is to carry out an atmospheric corrosion analysis on low carbon steel in the form of plates and elbows in the port area of Belawan. The exposure of the test specimen was carried out at five locations for 12 months. The location points are notated as A, B, C, D, and E. The process of specimen exposure and data collection followed the ASTM G-1 and ASTM G-50 standards. The measurement results indicated a slight difference in the corrosion rate at each location. Location C and D have the highest corrosion rate and location A has the lowest corrosion rate. Meanwhile, for locations B and E have a corrosion rate value that is not much different from location A. This difference in value is probably a consequence of the distance from the exposure location to the seaside. Locations C and D are adjacent to the seaside while the other locations are not. The steel plate has an average value of corrosion rate 0.2214 mpy and steel elbow has a rate of 0.2412 mpy. From the measurement results obtained, the two specimens exposed at each location are still in the "outstanding" category.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call