Abstract

The application of at-line NIR transmittance spectroscopy on supernatant samples from Chinese Hamster Ovary Cells (CHO) based monoclonal antibody (Mab) cultivation processes spanning several scales from 2.5L to 1000L, cell-lines and development years is described. The collected and preprocessed spectra were used to do process state estimation and to obtain several culture parameters. Multivariate process trajectories were computed from NIR spectra acquired at-line. These were used to enhance process understanding across different scales up to industrial scale, assess batch-to-batch variability, and examine the relative importance of different sources of process variability. Many parameters of interest in industrial cell culture, like nutrient or product concentrations can be reliably estimated by NIRS with an accuracy of 15% or better, compared to reference methods General calibrations (scale and cell-line independent) are valid across a range of process conditions and different feed regimes. The proposed approach is therefore applicable throughout process development as well as to existing large-scale validated CHO bioprocesses for continuous improvement.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.