Abstract

AbstractThis paper presents an asynchronous SAR ADC featuring a self‐timed track‐and‐hold (STH) architecture. The design aims to address the common timing issue of divider‐based clock generation, where the fixed‐time track‐and‐hold (FTH) period often results in incomplete conversions due to prolonged conversion times time due to comparator metastability. To alleviate the degradation of the ENOB induced by these delays, the proposed STH method is introduced so that more conversion period is secured without requiring a high‐speed input clock. Based on measurements, the proposed STH method achieves up to 0.7 bit improvement over the conventional FTH approach as conversion time increases.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call