Abstract
AbstractThis paper presents an asynchronous SAR ADC featuring a self‐timed track‐and‐hold (STH) architecture. The design aims to address the common timing issue of divider‐based clock generation, where the fixed‐time track‐and‐hold (FTH) period often results in incomplete conversions due to prolonged conversion times time due to comparator metastability. To alleviate the degradation of the ENOB induced by these delays, the proposed STH method is introduced so that more conversion period is secured without requiring a high‐speed input clock. Based on measurements, the proposed STH method achieves up to 0.7 bit improvement over the conventional FTH approach as conversion time increases.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.