Abstract

This paper proposes a power control of LLC resonant inverter for an induction furnace using asymmetrical duty cycle control (ADC) with phase limit to guarantee zero voltage switching (ZVS) operation and protect switching devices from spike current during the operation. The output power can be simply controlled through duty cycle of gate signals of a full-bridge inverter. With the phase limit control, non-ZVS operation and spike current caused by a change of duty cycle with fixed frequency and load Curie's temperature can be eliminated. Theoretical and simulation analyses of the proposed method have been investigated. The experimental results of heating a 300 g of Tin from room temperature until it is melted at 232 °C provided.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.