Abstract
BackgroundImplantation failure is not only a major cause of early pregnancy loss, but it is also an obstacle to assisted reproductive technologies. The identification of potential circulating biomarkers for recurrent miscarriage (RM) and/or recurrent implantation failure would contribute to the development of novel diagnosis and prediction techniques.MethodsMiR (miR-23a-3p, 27a-3p, 29a-3p, 100-5p, 127-3p and 486-5p) expression in the villi, decidual tissues and peripheral blood plasma and serum were validated by qPCR, and the localization of miRs in the villi and decidual tissues of RM and normal pregnancy (NP) women were detected by in situ hybridization. The invasiveness of HTR8/SVneo cells was determined using a Transwell assay. The predictive values of miRs for RM and the outcome of IVF-ET were respectively calculated by the receiver operating characteristic analysis.ResultsThe signals of six miRs were observed in the villi and decidual tissues of RM and NP women. The villus miR-27a-3p, miR-29a-3p and miR-100-5p were significantly up-regulated, whereas miR-127-3p and miR-486-5p appeared to be down-regulated in RM women compared to NP women. The invasiveness of HTR8/SVneo cells transfected with miR-23a-3p mimics was evidently weakened, whereas that of cells transfected with miR-127-3p mimics was obviously enhanced. The peripheral blood plasma levels of miR-27a-3p, miR-29a-3p, miR-100-5p and miR-127-3p were significantly increased, whereas that of miR-486-5p was remarkably decreased in RM compared to NP women. By contrast, serum miR-23a-3p and miR-127-3p were significantly decreased, whereas that of miR-486-5p was remarkably increased. The combination of six plasma miRs levels discriminated RM with a sensitivity of 100% and a specificity of 83.3%, whereas that of six serum miRs levels showed a sensitivity of 78.3% and a specificity of 93.1%. In the IVF-ET cohort, the significantly decreased peripheral blood plasma levels of miR-23a-3p, miR-27a-3p, miR-100-5p and miR-127-3p, and the serum levels of miR-100-5p and miR-486-5p, in addition to the significantly increased serum level of miR-27a-3p, were found to be associated with the failure of ET. Moreover, the combination of plasma miR-23a-3p, miR-27a-3p, miR-29a-3p, miR-100-5p, miR-127-3p and miR-486-5p levels discriminated the outcome of IVF-ET with a sensitivity of 68.1% and a specificity of 54.1%, whereas the combination of plasma miR-127-3p and miR-486-5p levels showed a sensitivity of 50.0% and a specificity of 75.3%.ConclusionsCirculating miR-23a-3p, miR-27a-3p, miR-29a-3p, miR-100-5p, miR-127-3p and miR-486-5 might be involved in RM pathogenesis and present potential diagnostic biomarkers for RM. Meanwhile, these miRs, in particular miR-127-3p and miR-486-5p, provide promising prediction indexes for the outcomes of IVF-ET.
Highlights
Implantation failure is a major cause of early pregnancy loss, but it is an obstacle to assisted reproductive technologies
Circulating miR-23a-3p, miR-27a-3p, miR-29a-3p, miR-100-5p, miR-127-3p and miR-486-5 might be involved in recurrent miscarriage (RM) pathogenesis and present potential diagnostic biomarkers for RM
By searching the human serum database, we found that in addition to miR-100-5p and miR-486-5p, another four miRs, miR23a-3p, miR-27a-3p, miR-29a-3p and miR-127-3p, which were screened to be differentially expressed in RM patients with fold changes ranging from 1.1 to 1.5, and P < 0.05 (Additional file 1: Table S1), are presented in human peripheral blood
Summary
Implantation failure is a major cause of early pregnancy loss, but it is an obstacle to assisted reproductive technologies. The identification of potential circulating biomarkers for recurrent miscarriage (RM) and/or recurrent implantation failure would contribute to the development of novel diagnosis and prediction techniques. Implantation failure is a major cause of early pregnancy loss, but it is an obstacle to the significant improvement of assisted reproductive technologies [2, 3]. The identification and evaluation of potential circulating biomarkers for RM and/or recurrent implantation failure would undoubtedly contribute to the development of novel diagnosis and prediction techniques
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.