Abstract
While P-wave duration (P-dur) and dispersion (P-disp) could both reflect fractionated and inhomogeneous propagation of sinus cardiac impulses, and may therefore be associated with each other, a clear relationship has not been extensively studied. We studied these markers as well as the significance of P-wave terminal force in lead V1 (PTFV1) in relation to the P-wave axis (P-axis). We appraised our previously studied sample of 500 consecutively numbered, otherwise unselected, electrocardiograms (ECGs) of outpatients from the University of Massachusetts, Worcester, Massachusetts, for the foregoing P-wave characteristics. P-disp, defined as the difference of the duration between the widest and narrowest P wave, and the greatest P-dur after a 12-lead ECG search, was measured manually to the nearest 10 ms. PTFV1 was considered positive when > or = 40 mm2 terminal deflection was present on biphasic P waves on lead V1. Normal P-axis was considered 0 degrees to +75 degrees by manually constructing the mean frontal plane electrical P-axis from standard limb leads. After excluding those with atrial arrhythmias, paced rhythms, errors in lead placement, P waves with low amplitude or overall technically poor tracing, 428 ECGs formed our final sample. P-dur was strongly associated with P-disp (P < 0.0001), but the correlation remained weak (r = 0.42). Overall, P-dur was not significantly associated with P-axis but when divided into tertiles and quintiles, the significance was evident within the range of the normal P-axis, particularly 0 degrees to +60 degrees (P < 0.0001). In a subanalysis of 380 ECGs that had appreciable biphasic P waves on lead V1, PTFV1 was noted on 178 (47%) ECGs and was significantly associated with P-dur (P < 0.0001), P-disp (P < 0.0001), and P-axis (P = 002). When considering P-axis in tertiles and quintiles, P-dur was greater in patients with a positive PTFV1 and significant within the normal range of the P-axis, especially from 0 degrees to +60 degrees . P-dur, P-disp, and PTFV1 appear to share a significant tripartite association in relation to the normal P-axis, particularly when P-axis ranges 0 degrees to +60 degrees . Therefore, for optimal clinical assessment, these markers should be evaluated in relation to the normal P-axis.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.