Abstract

There is a paucity of investigation which demonstrates a predictor of mitral regurgitation (MR) worsened after aortic valve replacement (TAVR). The aim of this study was to identify the predictor of worsened MR after transcatheter TAVR. We retrospectively studied a total of 209 patients with mild or less MR at baseline who underwent TAVR for the treatment of severe aortic stenosis with the balloon-expandable device. We found the presence of MR worsened after TAVR in 6% (12 patients) of all patients. Moderate or more postprocedural aortic regurgitation (AR) (odds ratio, 8.104; 95% confidence interval, 1.78-36.87; P=.007) was identified as a predictor of MR worsening after TAVR. In-hospital outcomes indicated that patients within whom MR worsened suffered congestive heart failure more than those with unchanged or improved MR after TAVR (P<.05). Significant postprocedural AR was associated with MR worsened from mild or less to moderate or more after TAVR. Worsened MR might affect in-hospital congestive heart failure.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.