Abstract

The associations of long-term exposure to various constituents of fine particulate matter (≤2.5μm in aerodynamic diameter, PM2.5) air pollution with lung function were not clearly elucidated in developing countries. The aim was to evaluate the associations of long-term exposure to main constituents of PM2.5 with lung function in China. This is a nationwide, cross-sectional analysis among 50,991 study participants from the China Pulmonary Health study. Multivariable linear regression models were used to obtain differences of forced expiratory volume in 1s (FEV1), forced vital capacity (FVC), FEV1/FVC, peak expiratory flow (PEF), and forced expiratory flow at 25-75% of exhaled FVC (FEF25-75%) associated with an interquartile range (IQR) change of PM2.5 or its constituents. Residential annual PM2.5 levels varied from 26μg/m3 to 92μg/m3 (average: 53μg/m3). An IQR increase of PM2.5 concentrations was associated with lower FEV1 (19.82mL, 95% CI: 11.30-28.33), FVC (17.45mL, 95% CI: 7.16-27.74), PEF (86.64mL/s, 95% CI: 59.77-113.52), and FEF25-75% (31.93mL/s, 95% CI: 16.64-47.22). Black carbon, organic matter, ammonium, sulfate, and nitrate were negatively associated with most lung function indicators, with organic matter and nitrate showing consistently larger magnitude of associations than PM2.5 mass. This large-scale study provides first-hand epidemiological evidence that long-term exposure to ambient PM2.5 and some constituents, especially organic matter and nitrate, were associated with lower large- and small- airway function.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call