Abstract

Background & Objective:Endotracheal intubation is routinely performed in the critical situations. In order to prevent microaspiration and tracheal injury endotracheal cuff pressure is important to remain constant between 20 and 30 cmH2O. Positive pressure ventilation, duration of intubation, body temperature, and body movements can alter endotracheal cuff pressure. This survey was conducted to evaluate core body temperature and cuff pressure relation with airway pressure simultaneously.Methods:This was a descriptive analytic study conducted from March 2018 to July 2018 on 150 intubated patients in the emergency department. All were ventilated with SIMV mode and had Ramsi sedation level of 2-3. Mean airway pressure was measured simultaneouly with core body temperature measurement from ventilator monitor. All these parameters were measured 10 times each hour and documented.Results:There was a statistically meaningful relation between airway pressure and cuff pressure in the primary evaluation (P=0.02, r=0.19), while none of the subsequent evaluations showed meaningful relation (P>0.05). No significant relation was found between cuff pressure and core body temperature in any of the measurements (P>0.05).Conclusion:The pressure of cuff should be checked repeatedly after intubation because of substantial variation over time. Factors other than core body temperature and airway pressure can influence cuff pressure.

Highlights

  • Endotracheal intubation is routinely performed in the critical situations.[1]

  • All intubated patients who were ventilated with SIMV mode in the emergency department of Tabriz Imam Reza hospital, 150 patients, entered the study

  • Mean airway pressure was measured hourly simultaneous with core body temperature measurement from ventilator monitor

Read more

Summary

Introduction

Endotracheal intubation is routinely performed in the critical situations.[1]. For preventing microaspiration and tracheal injury endotracheal cuff pressure is important to remain constant between 20 and 30 cm H2O.2 Positive pressure ventilation, duration of intubation, body temperature, and body movements can alter endotracheal cuff pressure.[3]. Endotracheal intubation is routinely performed in the critical situations.[1] For preventing microaspiration and tracheal injury endotracheal cuff pressure is important to remain constant between 20 and 30 cm H2O.2. Duration of intubation, body temperature, and body movements can alter endotracheal cuff pressure. This survey was conducted to evaluate core body temperature and cuff pressure relation with airway pressure simultaneously. Mean airway pressure was measured simultaneouly with core body temperature measurement from ventilator monitor. All these parameters were measured 10 times each hour and documented. Factors other than core body temperature and airway pressure can influence cuff pressure

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call