Abstract

Global Initiative for Asthma (GINA) reports emphasize the use of validated and simple tools in order to assess the level of asthma control, as the Asthma Control Test (ACT). However, an ACT does not include assessment of airway inflammation, which is better reflected when measuring nonspecific bronchial hyperresponsiveness (BHR). The authors aimed to find out if the level of asthma control quantified by an ACT correlates with BHR and pulmonary function tests. 118 asthmatics participated in the study. All patients completed an ACT. The scores of the ACTs were compared with pulmonary function tests and BHR assessed with the methacholine challenge test and expressed as a provocative concentration of methacholine, inducing a 20% decline in the FEV1 (PC20 M in mg/ml). Patients with controlled asthma amounted to 52 (44%) while those with uncontrolled asthma amounted to 66 (56%). In patients with controlled asthma (ACT score ≥ 20) the mean geometric value of PC20M was 2.72 mg/ml (range from 0.25 to > 8.0), whereas 0.94 mg/ml (range from 0.28 to 8.0) (p = 0.02) was observed in patients with uncontrolled asthma (ACT score < 20). Almost 64% (21/33) of uncontrolled asthmatics achieved normal lung function (FEV1 > 80% pred. value) while 19% (5/26) patients with controlled asthma presented an FEV1 < 80% predicted value. Asthma duration in years in controlled asthmatics was significantly shorter than in uncontrolled patients (6.2 ± 8.9 vs. 12.0 ± 11.4, p = 0.005) CONCLUSION: In determining the most accurate level of asthma control it is reasonable to use an ACT in conjunction with BHR, which provides more accurate assessment of bronchial inflammation than ventilatory parameters alone.

Highlights

  • Global Initiative for Asthma (GINA) reports emphasize the use of validated and simple tools in order to assess the level of asthma control, as the Asthma Control Test (ACT)

  • Studies have shown that asthmatic patients with an adequate control of their symptoms might be still at risk of severe exacerbations associated with underlying airway inflammation [5]

  • Due to the asthma control approach regarding asthma management, it was of interest to find if the level of asthma control assessing presented in an ACT correlates with the bronchial hyperresponsiveness (BHR) and pulmonary function test

Read more

Summary

Introduction

Global Initiative for Asthma (GINA) reports emphasize the use of validated and simple tools in order to assess the level of asthma control, as the Asthma Control Test (ACT). In our study the level of asthma control assessed by a subjective numeric tool (ACT) was compared to the pulmonary function test and measurement of BHR.

Results
Conclusion
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.