Abstract

BackgroundThe use of neoadjuvant therapy (NAT) in patients with early breast cancer is becoming increasingly common. The purpose of this study was to explore the combined use of breast pathology cabinet X-ray system (CXS) to accurately assess the response to neoadjuvant treatment of breast cancer and establish a standard evaluation system.MethodsA total of 100 patients with breast cancer after neoadjuvant treatment were randomly selected. Preoperative imaging evaluation of tumor masses were significantly degenerated, and they were randomly divided into experimental and control groups of 50 cases each. Compared with the traditional two methods of material extraction, the effective material extraction rate is comparative. Take the two largest diameters of the largest two-dimensional surface of the tumor bed as the measurement object, the macro-description value is D1/D2, the radiographic system description measurement value is the experimental group d1/d2, and the correction under the microscope is worth the true size of the tumor bed H1/H2 as the final test standard, calculate the difference between D1/D2 and d1/d2 with H1 and H2, and compare the difference between d1− H1, d2 − H2 and D1− H1, D2 − H2.ResultsThe average group of tissue samples in the experimental group was 16.4, and the average group of tissue samples in the control group was 16.7, and there was no difference between the two groups; The effective tissue blocks of tumor bed samples in the experimental group were11.8, and the control group was 7.5. There is difference between the two groups. The average effective percentage of tumor bed in the experimental group was 72%, and the average effective percentage of tumor bed in the control group was 44.8%. The difference was also statistically significant; d1− H1, d2 − H2 and D1− H1, D2 − H2 are all different.ConclusionsCXS assists the collection of breast tumor bed, which can significantly improve the efficiency of tumor bed collection and save the cost of collection. Compared with the maximum diameter of the tumor bed by eyes, the CXS mapping value is closer to the value measured under the microscope.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.