Abstract
In this study, the influence of various parameters such as determination methods and step height and length of incremental flux on critical flux values were investigated. Experiments were carried out on a pilot-scale membrane bioreactor (MBR) treated municipal wastewater. Three of the five critical flux determination methods, such as flux linearity, 90% permeability and flux cycling conducted in this study, indicated a decline in critical flux values as the step height of incremental flux increased. However, the hysteresis method and the two-third (2/3) flux limitation method showed an increase and independence of critical flux to the step height of incremental flux, respectively. On the other hand, the step length of incremental flux had no obvious effect on critical flux values evaluated by all critical flux determination methods. Like critical flux, sustainable flux has negative relationship with the increase of step height but no influence of step length was found in this study.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.