Conjunctival impression cytology was performed on 236 Indonesian preschool children, half of whom had mild xerophthalmia and half of whom were age-matched controls. We devised an applicator that applies a paper disk of fixed area to the conjunctiva with even pressure. The disk applicator was used to collect impression cytology specimens from the temporal bulbar conjunctiva of one eye while the original strip technique was used on the other eye. Mean (+/- SD) serum retinol values for children with normal and abnormal discs were 22.0 +/- 8.6 micrograms/dL and 18.0 +/- 7.2 micrograms/dL P less than .0001). Mean serum values for normal and abnormal strips were 21.7 +/- 8.6 micrograms/dL and 19.0 +/- 7.7 micrograms/dL (P less than .03). Specimens obtained with the new disk applicator corresponded more closely with serum vitamin A levels and therefore vitamin A status than those obtained with the traditional strip technique.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.