Abstract
ABSTRACT Objectives: The study’s objective is to evaluate the fracture resistance of a tooth that has had endodontic treatment and has been rebuilt using various post and core systems. Materials and Methods: Thirty-six extracted premolar teeth of similar sizes were picked, and at random, they were separated into three groups: group A received stainless-steel posts, group B received zirconia fiber posts, and group C received glass fiber posts. Dual-cured resin cement was used to cement each post. The acrylic resin blocks have samples imbedded in them. Additionally, fracture loads were measured while a compressive force was given to the tooth at a crosshead speed of 1 mm/minute. The one-way analysis of variance F-test and post hoc Tukey’s test were then used to analyze the results. Results: When the mean values and standard deviation were compared, it was found that glass fiber posts had the highest fracture resistance, followed by posts made of zirconia fiber, while stainless-steel posts had the lowest fracture resistance Conclusion: When compared to zirconia posts and stainless-steel posts, glass fiber posts had the highest level of fracture resistance.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.