Abstract

The objective of this study was to evaluate the diagnostic accuracy of hystero-salpingography (HSG) in detecting uterine cavity abnormalities in infertile patients, with reference to hysteroscopy as the gold standard method. 60 infertile women were investigated with both HSG and hysteroscopy. Statistical analysis was performed. As a test for the detection of uterine cavity abnormalities, HSG in comparison with hysteroscopy had 60% sensitivity, 90% specificity, 10% false positive value and 40% false negative value. HSG is not able to diagnose polyps, septum and submucous fibroids with significant accuracy. Therefore hysteroscopy is indicated for confirmation.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.