Abstract
It is important to detect post-liver biopsy hemorrhage early and confirm hemostasis in the clinical setting. Contrast-enhanced ultrasound (CEUS) is a sensitive and highly specific tool for detecting active bleeding. The aim of this study was to investigate the rate of detection of track microbubble flow signals on CEUS with perflubutane following liver biopsy and to assess the disappearance of these signals. Microbubble flow signals along the needle track on CEUS were examined in 100 patients who underwent percutaneous US-guided liver biopsies. The microbubble flow signals were examined repeatedly until their disappearance. The patients were followed up with clinical and laboratory data to detect clinically significant hemorrhaging. Microbubble flow signals on CEUS following percutaneous liver biopsy were seen in 33% of the patients. There were no significant differences in the platelet count, prothrombin time or length of the biopsy specimen between the patients with and those without microbubble flow signals on CEUS. The microbubble flow signals disappeared over time in all patients. There were no cases of clinically significant hemorrhaging in the present study. Track microbubble flow signals on CEUS are frequently observed after biopsies. The disappearance of a microbubble flow signal is a useful index for confirming hemostasis of postbiopsy hemorrhaging.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.