Abstract
Double loop electrochemical potentiokinetic reactivation (DL-EPR) was applied to evaluate thermal aging of 308L stainless steel weld metal. It was found that the activation and reactivation peaks of DL-EPR curve were induced by dissolution of austenite and δ-ferrite, respectively. Before saturation of hardness, the linear relationship between reactivation ratio and hardness could be used for assessing the thermal aging-induced hardening. In the following thermal aging process, the reactivation ratio is applicable to assess the occurrence of the saturation of thermal aging-induced hardening. The results demonstrated that the DL-EPR test is applicable to assess the evolution of thermal aging.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.