This study was carried out to investigate leakage/transport across the bag material of six outer cryopreservation bags in common use within NHS Blood and Transplant. In order to do this two different leak testing procedures; coloured dye and hydrogen tracer gas, were used. The data obtained show that a coloured dye cannot permeate through the materials both at room temperature and following storage at liquid nitrogen temperature (-196°C). In addition, when filled with the smallest elemental molecule, hydrogen, in the form of a tracer gas, all of the bags only allowed trace amounts of hydrogen to escape, either through the seal or the bag material. The data indicated that each of the bag materials tested would be capable of preventing bacterial or viral cross-contamination as long as the material remained intact.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.