Abstract
Manganese substituted hydroxyapatite nanoparticles (nMnHAp) were produced using the ultrasonic wet chemical method. The elemental analysis was performed using Scanning Electron Microscopy (SEM) with integrated Energy Dispersive X-ray Spectrometry (EDX). The mass attenuation coefficients of manganese substituted hydroxyapatite nanoparticles have been measured at 59.5 keV gamma energy emitted from 241Am radioisotope annular source with 50 mCi activity by using Ultra Low Energy Germanium Detector. These values are found to be in good agreement with theoretical values based on calculated XCOM data. Electron densities and effective atomic numbers were calculated by using the mass attenuation coefficients. Also, the mass attenuation coefficient of the real bone was determined as experimentally. The obtained results may provide information on how much radiation is transmitted through the sample when they are exposed to gamma-rays at 59.5 keV by comparing real bone.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.