Abstract

Application of a helium-cooled divertor together with the dual-coolant blanket concept is considered favourable for achieving a high thermal efficiency of the power plant due to its relatively high coolant outlet temperature. A new FZK He-cooled modular divertor concept with integrated pin arrays (HEMP) is introduced. Its main features and function are described in detail. The result of the thermalhydraulic analysis shows that the HEMP divertor concept has the potential of resisting a heat flow density of at least 10-15 MW/m 2 at a reachable heat transfer coefficient of approx. 60 kW/m 2 K and a reasonable pumping power. Integration of this divertor concept into the power conversion system using a closed Brayton gas turbine system with three-stage compression leads to a net efficiency of the blanket/divertor cycle of about 43 %.