Abstract

The high-resolution electrocardiography is known to be a useful tool for extraction and analysis of low-amplitude signal components. We found the high-resolution standard and synthesized orthogonal electrocardiography leads may be useful for precise evaluation of the zone of acute myocardial infarct necrosis. We found high-resolution electrocardiography may be useful for precise location of the site of the myocardial necrosis and assessment of the severity of impaired left-ventricle systolic function of patients with ST-elevation myocardial infarct (STEMI) in the acute phase. High-resolution (1 MHz) ECG from 4 groups were collected: healthy controls (13), patients with anterior (10), inferior STEMI (19) and 12 patients with infero-lateral AMI). The three orthogonal leads X, Y, Z were synthesized from the 12-standard leads by known transformation. The possibility for facilitated and fast performance of this examination in clinical conditions, including emergency, the lack of necessity of specially trained staff for carrying out the examination and interpretation of the results, as well as the very low prime cost, make this electrophysiological method very suitable for application in the routine clinical practice for qualitative and quantitative assessment of patients with acute coronary syndromes.

Highlights

  • In principle the signal-averaged high-resolution electrocardiography (SAECG) is a technique involving computerized analysis of small segments of a standard electrocardiography (ECG) in order to detect late potentials [1,2]

  • We involved into analysis recordings from Public Accessible PTB Diagnostic ECG Database [2] - highresolution ECG database (12 standard leads + 3 orthogonal leads), because it is collected from healthy volunteers and patients with different heart diseases, which is supported with complete information about the diagnosis, haemodynamics and therapy for each patient

  • We examined the possibility for improvement of the acute myocardial infarct (AMI) diagnostics

Read more

Summary

Introduction

In principle the signal-averaged high-resolution electrocardiography (SAECG) is a technique involving computerized analysis of small segments of a standard electrocardiography (ECG) in order to detect late potentials [1,2]. The high resolution SAECG and vectorcardiography (VCG) was employed recently as a method for qualitative and quantitative diagnosis of patients with acute myocardial infarct (AMI).

Results
Conclusion

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.