Abstract

Background: The most common factor that could lead to dryness is the accelerated tear evaporation rate. Controlling the tear evaporation rate is increasingly used as a method to control dry eye complications. The present study explores the effects of different tear supplements formulations on tear film evaporation rate. Objective: This study aimed to evaluate the short-term effects of Systane ULTRA and Artelac Advanced eye drops on the tear film evaporation rate. Methods: Fifteen male dry eye subjects were enrolled in the current study. Tear film parameters were observed at several time points post installation (10, 20, 30, and 60 min). The tear film parameters observed in the current study were tear evaporation rate, noninvasive breakup time (NITBUT) and tear meniscus height (TMH). Two visits were required to conduct this study. One visit was conducted to assess the physiological tear film parameters with the use of Systane® ULTRA eye drop. The other visit was conducted to assess tear film parameters with the use of Artelac Advanced eye drop. Results: The mean tear evaporation rate at baseline was 52.58 ± 23.24 g/m2 h. A box plot of tear evaporation showed a reduction in tear film evaporation rate after instillation of Systane eye drop. A drop in tear film evaporation rate of 14% was observed at 20 and 60 min time point after instillation of Systane ULTRA eye drop. A significant increase in NITBUT was found after instillation of Systane ULTRA (P = 0.01) and Artelac Advanced (P = 0.02). Conclusion: The current study indicates a significant improvement in the tear film parameters using both HP-Guar and hyaluronic acid formulations. However, it was apparent that the use of HP-Guar was superior to hyaluronic acid in controlling the tear evaporation rate in dry eye subjects.

Highlights

  • A healthy, stable preocular tear film plays a vital role in protecting, moisturizing, and nourishing the cornea

  • A box plot of tear evaporation showed a reduction in tear film evaporation rate after instillation of Systane eye drop

  • The current study indicates a significant improvement in the tear film parameters using both HP-Guar and hyaluronic acid formulations

Read more

Summary

Introduction

A healthy, stable preocular tear film plays a vital role in protecting, moisturizing, and nourishing the cornea. It helps maintain clear vision as it is considered the primary. Attempts have been made to control and manage complications of dry eye syndrome. Artificial tears are one of the most commonly used therapies that work by replacing tears and lubricating the ocular surface It helps in restoring corneal surface and goblet cell density and improving visual acuity [4]. Controlling the tear evaporation rate is increasingly used as a method to control dry eye complications. The present study explores the effects of different tear supplements formulations on tear film evaporation rate

Methods
Results
Discussion
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call