Abstract

Cathodic Protection of reinforced concrete is covered under BS EN ISO 12696. There are four criteria for protection stated in BS EN ISO 12696. They are based on gathering accurate instant off data between 0.1 and 1 s after switching off the power to the zone. Further interpretation is based on collecting data over time with the system switched off. These criteria are largely empirical in nature but have a proven track record. Collecting the instant off value with any degree of accuracy is critical to assessing the performance of a system in comparison to this standard. Unless the system has an adequate logging facility this is difficult to achieve. As systems age the logging becomes less reliable, and software and hardware updates mean accessing it can prove problematic. This article reviews depolarization data from 261 reference electrodes installed at three sites. The anode systems include conductive coating anode systems, mesh and overlay anode systems and discrete anode systems. The paper comments on the forms of curves obtained and the protection criteria. It suggests a simpler method of assessing decay curves that can be readily achieved using manual logging.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.