Abstract

Water quality sensors deployed on boats, buoys, and fixed monitoring stations along rivers allow high frequency monitoring at dense spatial and temporal resolutions. Research characterizing nitrate (NO3–N) delivery along extended reaches of navigable rivers, however, is sparse. Since land use and stream biogeochemistry can vary within agricultural watersheds, identifying detailed spatial patterns of stream NO3–N can help identify source area contributions that can be used to develop strategies for water quality improvement. Identifying spatial patterns is especially critical in agricultural watersheds that span multiple landscapes and have dynamic hydrological regimes. We developed and tested a new method that quantifies NO3–N delivery to streams at a high spatial resolution by continuously measuring stream NO3–N using a boat-deployed sensor. Traveling up the Iowa and Cedar Rivers (located within agricultural Upper Mississippi River Basin) and their major tributaries with the system, we automatically measured NO3–N concentrations every 15 s during four excursions spanning the months of May to August, 2018, and characterized stream NO3–N both laterally and longitudinally in river flow. Iowa River NO3–N concentrations were highest nearest the headwaters and gradually declined as the river flowed toward the Mississippi River. Conversely, Cedar River NO3–N concentrations increased from the headwaters toward the mid-watershed areas due to elevated NO3–N delivery from tributaries of the Middle Cedar River; NO3–N concentrations declined in the lower reaches. Our results confirm that NO3–N mitigation efforts should focus on level and intensely-farmed subwatersheds. Data collected with our sensor system compliments permanently deployed sensors and provides an option to support NO3–N removal efforts.

Highlights

  • Quantitative measurement of water quality from boats dates to at least 1864 when Secchi depths were recorded in the Mediterranean Sea [1]

  • Technological advancements have enabled in situ measurements of specific conductivity (SPC), nitrate–nitrogen (NO3 –N), turbidity, chloride, pH, chlorophyll a and many other parameters from moving boats, floating buoys, and fixed monitoring stations anchored to the shoreline and bridge abutments [5,6,7,8,9]

  • We developed an on-board flow-through system for continuous, boat-deployed water quality measurements

Read more

Summary

Introduction

Quantitative measurement of water quality from boats dates to at least 1864 when Secchi depths were recorded in the Mediterranean Sea [1]. Maher et al [6] used cavity ring down spectroscopy deployed on a small vessel to measure dissolved 12 CH4 , 13 CH4 , CO2 , and CO2 at ≈6 km h−1 in a 15-km stream reach and estuary in Australia While these methods were satisfactory for the small spatial scales of interest to these studies, higher speeds are necessary if the research objective is to characterize water quality in long stream reaches of major rivers. High-speed monitoring becomes possible when sensors are moved on-board and sample water is pumped to the sensors [10] Using this method, several sensors can simultaneously measure multiple water quality constituents with the protection of a quiescent onboard reservoir as the boat travels upwards of 45 km h−1 [10].

Methods
Results
Conclusion
Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call