Abstract The goal of this work is the hydraulic capacity assessment of selected combined sewer systems in the city of Trnava. The selected sewer system constitutes from 160 sections 3.3 km long. Hydraulic capacity assessment will test sewer system, created in SeWaCAD program with design rainfall events with varied frequencies. The result of assessment showed that hydraulic capacity of combined sewer system did not meet requirements to properly work. Malfunctioning sewer pipelines must be changed. Design rain with frequency at least one in two years will be used as restoration model.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.