Abstract
Assessment of spleen size using the ultrasonography has become a standard practice in human. However, the assessment is not established method in experimental animals. To establish the index to assess the spleen size using ultrasonography, we measured the cross-section image of rabbit spleen during endotoxin shock. The image of the cross-section was appeared as triangle, and the height of the triangular image was defined as the spleen index. This spleen index showed strong correlation with the spleen weight. In conclusion, this method is suitable for observation of changes in rabbit spleen size and may reduce the number of rabbit in the longitudinal studies.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.