Abstract
New analytical methods based on liquid chromatography with electrospray tandem mass spectrometry (LC–MS/MS) have been developed and validated for assessing the exposure of greenhouse workers to acetamiprid. Both ambient (potential inhalation and dermal exposure) and internal dose (biological monitoring of urine samples) measurements were carried out. Potential inhalation exposure was assessed using Chromosorb 102 cartridges connected to air personal samplers. Potential dermal exposure was estimated by using whole body dosimetry. The measurement of actual exposure was done by analyzing the parent compound in urine samples of the applicators, after a solid-phase extraction (SPE) step. The methods showed a good accuracy (72–92%), precision (2–13%) and lower limits (few μg l −1). The validated approaches have been applied to assess potential and actual exposure of agricultural workers spraying acetamiprid in greenhouses. The results shown the need to wear personal protective equipment (suits) in order to reduce the absorbed dose of acetamiprid.
Published Version
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.