Abstract
The energy utilization efficiency of commercial photovoltaic (PV) pumping systems can be significantly improved by employing simple perturb and observe (P&O) maximum power point tracking algorithms. Two such P&O implementation techniques, reference voltage perturbation and direct duty ratio perturbation, are commonly utilized in the literature but no clear criteria for the suitable choice of method or algorithm parameters have been presented. This paper presents a detailed theoretical and experimental comparison of the two P&O implementation techniques on the basis of system stability, performance characteristics, and energy utilization for standalone PV pumping systems. The influence of algorithm parameters on system behavior is investigated and the various advantages and drawbacks of each technique are identified for different weather conditions. Practical results obtained using a 1080-Wp PV array connected to a 1-kW permanent magnet dc motor-centrifugal pump set show very good agreement with the theoretical analysis and numerical simulations.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.