Abstract
This study aimed to investigate occupational radiation exposure in cyclotron workers in Saudi Arabia and compare the doses received with the International Commission of Radiological Protection dose limits. We conducted a retrospective study of Hp (10) and Hp (0.07) in 144 workers in an 18-MeV dual beam (proton and deuteron) cyclotron facility in Saudi Arabia from 2015 to 2019. The workers included physicists, engineers, chemists, radiochemists, technicians, operators, and quality control chemists. Individual dosimetry was assessed using thermoluminescent dosimeters (TLDs) comprised of Harshaw detector crystals with LiF:Mg, Ti elements. The mean Hp (10) and Hp (0.07) doses averaged over the 5-year study period for all workers were 1.47 ± 0.15 and 1.54 ± 0.16 mSv, respectively. No worker received doses exceeding the annual dose limits. We recommend that workers wear ring dosimeters to estimate the dose to the extremities and dosimeters use an advanced type of absorber to discriminate between different types of radiation.
Talk to us
Join us for a 30 min session where you can share your feedback and ask us any queries you have
Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.