Abstract

This paper presents the results of a study investigating the correlation between the anticipated seismic performance of an ASCE 7 code-compliant steel building with special moment frames and its predicted performance as quantified using ASCE 41 analysis procedures and structural performance metrics. Analytical results based on component-level performances at the collapse prevention structural performance level indicate that special moment frames designed in accordance with ASCE 7, and its referenced standards, have difficulty satisfying the acceptance criteria in ASCE 41 for an existing building intended to be equivalent to a new building.