Abstract

Staging of bronchiolitis obliterans syndrome (BOS) following lung transplantation is based on declines in forced expiratory volume in 1 s (FEV(1)). The aim of this study was to evaluate the usefulness of (133)Xe ventilation scintigraphy in the early detection of BOS following living-donor lobar lung transplantation (LDLLT), to compare (133)Xe washout imaging with computed tomography (CT) findings for early detection of BOS following LDLLT, and to evaluate (133)Xe washout imaging by quantitative analyses. Subjects comprised 30 double-lung recipients and 1 single-lung recipient, who had undergone LDLLT at our institution and survived more than 1 year. Clinically diagnosed BOS developed in six recipients. Declines in graft function were evaluated using a combination of three methods, namely, dynamic spirometry, high-resolution CT (HRCT), and (133)Xe ventilation scintigraphy. Findings for all transplanted lungs were compared between CT and (133)Xe washout imaging. (133)Xe washout imaging was assessed using mean transit time (MTT) of bi-and unilateral lungs. Correlations between MTT of bilateral lungs and FEV(1)% were evaluated. Differences in MTT between BOS and non-BOS lungs, and between non-BOS and donor lungs were also evaluated on unilateral lungs. Appropriate cut-off values of MTT of unilateral lungs were set for the diagnosis of BOS. In all six BOS cases, prolonged-washout images of engrafted lungs revealed early-phase BOS with declines from baseline FEV(1), whereas only one BOS case could be detected using early CT findings of BO (bronchodilatation, decrease in number and size of pulmonary vessels, thickening of septal lines, and volume reduction). A significant correlation was identified between MTT and FEV(1)% (r = -0.346, P < 0.0001). MTT of unilateral lungs was significantly longer in BOS lungs than in non-BOS lungs (P < 0.0001). The cut-off MTT of unilateral lungs for the diagnosis of BOS was set at 64.77 s. Our data show that (133)Xe washout imaging offers excellent potential for early detection of BOS compared with early CT findings. Using (133)Xe washout imaging and MTT with radioactive tracer offers a noninvasive indication of selective ventilatory function in engrafted lungs following LDLLT. MTT appears useful for identifying BOS following LDLLT and allows quantitative evaluation of graft function in unilateral lungs.

Full Text
Published version (Free)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call