Abstract

Magnetometer is reference sensor of satellite that function to measure the vector of magnetic field during satellite enter the orbit. The magnetic field measurement vector will be employed in the Attitude Determination System (ADS) to calculate the satellite’s orientation with respect to the Earth. However, any misalignments or disturbances on the ADS can affect the orientation of the satellite in terms of the orbital position. Therefore, in this paper assessment of magnetic field on body axis and orbit axis of RazakSAT by using The International Geomagnetic Reference Field (IGRF) model. RazakSAT as references to verify the IGRF model by using residual analysis that percentage error less than 5% requirement from Astronautic Technology Sdn Bhd (ATSB). The result show, Y-axis and Z-axis from orbit frame meet the requirement of ATSB is less than 5%.