PurposeTo evaluate clinical outcome after surgery of idiopathic epiretinal membranes (ERM) with internal limiting membrane (ILM) peeling using a commercial combination of Brilliant blue G (BBG, 0.25 mg/ml) with 4% polyethylene glycol (PEG).MethodsIt was a prospective, single-center study. Macular surgery was performed due to ERM (n = 18) by two experienced surgeons. Exclusion criteria were secondary ERM, previous retinal surgery and pharmacological treatment. Best-corrected visual acuity (BCVA), optical coherence tomography (OCT), and multifocal ERG (RETIscan) were assessed at baseline and three months after surgery.ResultsThe BCVA improved from baseline 0.4 ± 0.13 logMAR to 0.3 ± 0.2 logMAR after three months (p > 0.05). The mean central foveal thickness was reduced from 407 ± 85 μm to 366 ± 56 μm after three months (p > 0.05). At baseline, the mean P1 amplitude (nV/deg2) was 53.5 ± 32.1 in ring 1 and 35.9 ± 20.1 in ring 2. Three months after surgery the mean P1 amplitude was comparable with 57.2 ± 16.3 in ring 1 and 38.0 ± 11.7 in ring 2 compared with the initial situation (p = 0.22 and p = 0.3, respectively).ConclusionBBG with 4% PEG can be used for ILM peeling in patients with idiopathic epiretinal membranes without any sign of short-term toxicity.

Highlights

  • A macular epiretinal membrane (ERM) is characterized by fibrocellular proliferation of the internal limiting membrane (ILM) [1]

  • The Best-corrected visual acuity (BCVA) improved from baseline 0.4 ± 0.13 logMAR to 0.3 ± 0.2 logMAR after three months (p > 0.05)

  • Three months after surgery the mean P1 amplitude was comparable with 57.2 ± 16.3 in ring 1 and 38.0 ± 11.7 in ring 2 compared with the initial situation (p = 0.22 and p = 0.3, respectively)

Read more

Summary

Methods

Macular surgery was performed due to ERM (n = 18) by two experienced surgeons. Exclusion criteria were secondary ERM, previous retinal surgery and pharmacological treatment. Best-corrected visual acuity (BCVA), optical coherence tomography (OCT), and multifocal ERG (RETIscan) were assessed at baseline and three months after surgery

Results
Introduction
Materials And Methods
Discussion
Conclusions
Disclosures
Wise GN
Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.