Background: Off-pump coronary artery bypass grafting (OPCAB) on a beating heart with a LIMA graft to the LAD is established for patients with one vessel disease. The aim of the study was to assess the LIMA patency noninvasive by transcutaneous duplex ultrasound. Methods: 25 patients (16 male, 9 female, mean age 58±13 yr) with LIMA grafts to LAD by OPCAB procedures were studied 7–20 days after surgery. Doppler velocity parameters were measured by use of a 7 MHz transducer placed in left intercostal space. The conventional coronary angiographies performed showed the LIMA graft patent. Results: In all cases a typical biphasic pattern of blood flow was recorded with forward flow in both systole and diastole respectively. Under basal conditions the mean peak velocities in systole were 0.36 m/s and the mean peak velocities in diastole were 0.27 m/s with a mean systolic/diastolic ratio of 1.33. Conclusion: Transcutaneous Doppler ultrasound is useful in the detection of the LIMA graft flow. This non-invasive technique may find applications for routine postoperative follow-up of patients with LIMA grafts.

Full Text
Paper version not known

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.