Abstract

Acoustic parameters obtained from calibrated acoustic equipment are part of the minimum soundscape reporting requirements as stated in Annex A of ISO 12913-2. To dynamically monitor the acoustic environment of a large area, a large network of acoustic sensors could be deployed, albeit at significant cost. Micro-Electro-Mechanical Systems (MEMS) microphones offer compact, low-cost and high-performance alternatives to traditional analog microphones. In particular, the use of Inter-IC Sound (IS) communication allows MEMS microphones to be conveniently used in concert with I2S output interfaces for sound actuation. The performance of several IS MEMS Microphones was compared to that of an IEC 61094-4:1996 WS2F microphone in an anechoic chamber and a series of digital filters was designed to compensate for the differences in frequency response. The noise floor, compensated frequency response, acoustic parameter accuracy of IS MEMS were evaluated and recommendations regarding the suitability of the IS MEMS were provided.

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.