Abstract

The relationship between surface diaphragm mechanomyography (sMMGdi), as a noninvasive measure of inspiratory muscle mechanical activation, and crural diaphragm electromyography (oesEMGdi), as the invasive gold standard measure of diaphragm electrical activation, had not previously been examined. To investigate this relationship, oesEMGdi and sMMGdi were measured simultaneously in 6 healthy subjects during an incremental inspiratory threshold loading protocol, and analyzed using fixed sample entropy (fSampEn). A positive curvilinear relationship was observed between mean fSampEn sMMGdi and oesEMGdi (r = 0.67). Accordingly, an increasing electromechanical ratio was also observed with increasing inspiratory load. These findings suggest that sMMGdi could provide useful noninvasive measures of inspiratory muscle mechanical activation.