Abstract

Objective. The purpose of this study was to compare 2 film systems and several digital intraoral systems with regard to visual image quality through use of a test phantom developed for this purpose. Study Design. The detectors used for digital imaging were as follows: Computed Dental Radiography (CDR), Digora, Dixel, and Sens-A-Ray without scintillator layer. Two types of digital images were prepared for the observer performance test: one with original gray scales and another with contrast enhancement. Images with and without enhancement from the 4 systems were displayed to 7 observers. The change in the average number of perceptible holes was plotted against exposure, and modified perceptibility curves were created and compared with curves for the film systems. The exposure level at which the maximum number of holes was perceived was defined to be optimum. The optimum exposure levels were determined for each digital system and compared with that of the film systems. At the optimum exposure, the average maximum numbers of perceptible holes in each digital system with and without contrast enhancement were compared with the maximum numbers for the film systems. The minimum exposure levels were determined to be those at which the number of perceptible holes exceeded the number for film, and the possibility of exposure reduction was evaluated. Results. All digital systems except the Digora system showed lower optimum exposures than E-speed film. In all digital images without enhancement, however, the maximum number of perceptible holes was significantly lower than that for the film systems at that exposure. With contrast enhancement, all digital systems except the Sens-A-Ray system showed visibility superior to that of the film systems. With the CDR, Digora, and Dixel systems, exposures could be further reduced by a considerable amount, with greater retention of information than was associated with film. Conclusions. Our results strongly suggest that digital systems, if properly used, can exceed film systems in the detection of small mass changes. (Oral Surg Oral Med Oral Pathol Oral Radiol Endod 1999;87:123-9)

Talk to us

Join us for a 30 min session where you can share your feedback and ask us any queries you have

Schedule a call

Disclaimer: All third-party content on this website/platform is and will remain the property of their respective owners and is provided on "as is" basis without any warranties, express or implied. Use of third-party content does not indicate any affiliation, sponsorship with or endorsement by them. Any references to third-party content is to identify the corresponding services and shall be considered fair use under The CopyrightLaw.